top of page

SERVICES

In all matters concerning Life and Fire Safety, Independent Design, Consultancy and Measurement-Testing services are carried out with the principle of "delivery on time, complete and with accuracy without doubt". The studies to be determined in line with this may include the whole process from the identification of the defect to the commissioning of the defect, as well as any stage (determination of the defect and/or design and/or preparation of the tender documents and/or the tender management and/or Application Technical Consultancy-Inspection and/or Measurement-Testing) can also be carried out.

DESIGN

Design studies are carried out with the necessary engineering optimization in line with computer-aided calculations by determining the correct design criteria for all systems concerning Fire Safety.

 

Design Services;

 - Gathering Information with On-Site Inspection,

 - Determination of Design Criteria,

 - Presentation of the Design Report to the Employer,

 - Design and Calculations,

 - Preparation of Commercial-Technical-Material Specifications,

 - Preparation of Bills of Materials and Discoveries (BOQ),

 - Preparing the Lists of Companies from which Offers Can Be Obtained,

 - Tender Management,

 - Preparation of Bid Evaluation Reports,

includes their work.

ADAL Projelendirme
ADAL Danışmanlık
CONSULTANCY

Consultancy studies are carried out by determining the right solutions and design criteria for all issues concerning Fire Safety, either at once or in parts.

 

Consultancy services;
  - Existing Building Review - Evaluation (Master Plan),
  - New Building Design Process - Technical Consulting,

  - Implementation Process - Technical Consulting,

  - Implementation Process - Application Control and Reporting,

  - Project management,
includes their work.

ADAL Deneme
MEASURING

Measurement-testing-reporting studies are carried out in order to determine the correct design criteria, working conditions and required performance rates of all systems concerning Fire Safety.

 

Measurement-Testing Services,

  - Fire Pump Performance,
  - Sprinkler System Performance,
  - Gas Extinguishing System Performance,

    Fully Dominant CO2 Exhaust Attempts

    Room Tightness Test (Door-Fan Testing),
  - Detection and Warning Systems Scenario Testings,
  - Emergency Lighting-Direction Systems Measurements,
is being done for

  - Examination of Existing System Projects,

  - Determination of Design Criteria,

  - Determination of the Lowest Performance Values,

  - Performing On-Site Measurement-Testing Works

   ( With FM Approved and Calibrated Devices ),

  - Reporting of Results,
includes their work.

The phrase "All Issues Concerning Fire Safety" above includes the following in detail:
  ●  Fire Prevention Means

   ◦  Inspection of Electrical-Mechanical and Architectural Installations/Systems

   ◦  Flammable Substance Control

   ◦  Igniting Substance Control

  ●  Passive Fire Protection Means

   ◦  Selection of Building and Furnishing Materials

   ◦  Ensuring Fire Resistance - Structural Integrity

   ◦  Fire Partitioning (Zoning)

   ◦  Fire Spread Prevention

  ● Life Safety Means

   ◦  Escape and Evacuation Routes

   ◦  Emergency Lighting

   ◦  Emergency Announcement (Announcement) System

   ◦  Emergency Routing and Marking

   ◦  Natural and Mechanical Smoke Extraction System

   ◦  Marking of Dangerous Goods

  ● Active Fire Protection Means

   ◦  Manual Intervention Means

    -  Indoor Fire Hose Cabinet Systems

    -  Outdoor Fire Hose Cabinet (Hydrant) and Water Cannon Systems

    -  Portable Extinguishers (Fire Extinguishers)

    -  Water Spray Systems

    -  Water-Foam Spray Systems

   ◦  Automatic Intervention Means

    -  Automatic Sprinkler Systems

    -  Automatic Foam Suppression Systems

    -  Automatic Gaseous Extinguishing Systems  

    -  Automatic Kitchen Hood Extinguishing Systems  

    -  Automatic Water Mist Suppression Systems

    -  Automatic Dry Chemical Extinguishing Systems

  ●  Pressurized Fire Water Supply Means

   ◦  Fire Water Storage Systems

   ◦  Fire Water Pressurization Systems

    -  Elevated Water Tank/Tank Systems

    -  Fire Pump Systems

   ◦  Sparkling Water Preparation and Mixing Systems

  ●  Fire Detection and Alarm System

   ◦  Coordination with Fire Detection Systems

   ◦  Coordination with Building Management System (BMS)

   ◦  Alignment with Extinguishing Systems

  ●  Preparedness

   ◦  Fire Brigade Response Planning

   ◦  Emergency Manuals

   ◦  Trainings

 

 

ADAL Konumu

Address

Dekon Plus Business Center No: 21
Umraniye - Istanbul

ADAL Telefon Numarası

Phone

T: +90 216 572 2325

ADAL E-Posta Adresi

Click for the Information Text of the Law on the Protection of Personal Data .

Chamber Sealing Test,  OSD Door Fan Test, Door Fan Trial, Room Leakage Test, Gas Extinguishing Test, Door-Fan Test, Door Fan Test,  Integrity Test, Room  Enclosure Integrity Test, FM200 Test, FM200 Trial, CO2 Trial, CO2 Test, Total Flooding, Extended Discharge, Local Application, Carbon Dioxide Trial, Carbon Dioxide Discharge Trial, Carbon Dioxide Discharge Test; Sprinkler Design, Sprinkler Project, Detection Project, Detector Placement, Evacuation Project, Fire Consulting Firm, Consultant, Fire Consultant Company, Fire Firm, Fire Consulting Firms,

© 2022 by AYG

Fire Consultant İbrahim YILMAZKAYA